Directions - google link: https://www.google.ie/maps/place/Stella+Maris,+Wicklow/@52.9717369,-6.0563819,17z/data=!3m1!4b1!4m2!3m1!1s0x4867b74e91ac29df:0x9d325a3b0ffb7d70?hl=en Exit 16 from M11 (Dublin Wexford) - drive through Rathnew village, turn right on set of lights after Rathnew cemetery. On the roundabout turn left, drive all the way passing through crossroads with set of lights. This is the town relief road. Up to another roundabout, go stright on this roundabout and then turn left on the second exit, this is a sharp left turn. This is the Ballyguile Beg road. There are a few ramps, a Montessori school on the right inside. The house is the last house on the right soon after the Montessori school. There is no parking in the property. Please find below map showing where to park the car: https://nzeb-opendoors.ie/wicklow-town-where-park By Bus, there is from Dublin city centre 133 bus, that stops just in front of the Montessori school mentioned above. Please contact Mariana at 087 9637509 who will be hosting the event if you need extra directions on the day.

Sat Nov 12 2016
2:00 PM
Event Passed
Wicklow Town
Spots left: 0
Booking Event ...


This 1960s detached house is undergoing a deep retrofit to achieve Enerphit passive house certification, using a step-by-step approach to the retrofit. The first step is currently underway and includes roof insulation between and over the rafters, an airtight membrane, external wall insulation to the north gable and chimney and new passive certifed rooflights, window and door. Future steps include additional insulation and airtightness membrane to timber frame walls and mechanical ventilation with heat recovery

Property Type: Co. Wicklow (Wicklow Town)
Status: Refurbished
Construction Year: 1960
Year of Renovation: 2015
Total Floor Area: 135 m²
Heating Demand (PHPP): 24 kWh/m²/yr
Primary Energy (PHPP):  kWh/m²/yr
Building Energy Rating (BER):  - Not Rated -
Walls: 0.13 W/m²K
Floors: 0.55 W/m²K
Roofs: 0.13 W/m²K
Windows:  W/m²K
Doors:  W/m²K
Air Tightness (changes per hour): 1 at 50 Pascals
Solar water heating
Mechanical ventilation with heat recovery
Wood burning stove
Renewable technology description: 